Shinnecock Inlet, NY with Tidal Forcing Results

 

The Zipped Archive contains the input and output files for each test case.

Version of ADCIRC Code

Zipped Archive

41_03

shinnecock_inlet_test_case

45_06

legacy_shinnecock_inlet

45_06

forward_shinnecock_inlet

45_08

serial_shinnecock_inlet

45_08

pc_shinnecock_inlet_failed

45_08

parallel_shinnecock_inlet

45_08

hot_shinnecock_inlet

50_99

serial_shinnecock_inlet

50_99

parallel_shinnecock_inlet

51.52.24

NetCDF Shinnecock Inlet

 

Information about the naming convention of test cases:

 

Legacy.  Several improvements have been made in recent versions of ADCIRC, including computation in double precision, the changeover to an improved algorithm for the integration of area around a node, and a recommended higher tolerance for iteration convergence. The result of these improvements is that output from v45.06 is not the same as (is better than) output from earlier versions using the same input data. In order to confirm that the differences are due to improvements and not bugs, v45.06 was recompiled to use single precision and the old area integration algorithm. The input files for the test cases were run just as they were for previous versions, including their old convergence tolerances—usually 1e-5. The resulting output data were labeled “legacy” and are for comparison with old versions of ADCIRC.

Forward. In order to compare the results from v45.06 with future versions of ADCIRC, the convergence tolerance was changed from 1e-5 to 1e-10 in the fort.15 files. The code was then run with no changes, i.e., in the default, as-distributed condition. The results were labeled “forward” on the results pages; these new input files will be used for current and future testing of ADCIRC.

Parallel. ADCIRC v45.06 was run in parallel on 2 CPUs to confirm that it gave the same results as in a serial run. The results were labeled “parallel” on the results pages.

Serial. This is a single processor run of an example problem; it is the same as the “forward” test of v45.06.

PC. The predictor-corrector time stepping algorithm was activated by selecting a negative time step. This test was added to the suite after I inadvertently introduced a bug into the predictor-corrector algorithm while fixing a different bug. Please note that the predictor-corrector algorithm has not been applied as broadly as ADCIRC’s default time stepping procedure. Note also that the predictor-corrector algorithm passed on four example problems (i.e., produced results very similar to “serial” test), but failed (blew up) on the Shinnecock Inlet problem.

Hot. This test was carried out by cold starting the example problem and running it until a hot start file was generated, approximately halfway through. Then it was hot started and run to completion. The results were compared to the “serial” case, where the simulations start from cold and run all the way to completion. The purpose was to ensure that a hotstart does not change or perturb the solution. I discovered and fixed two hotstart bugs with this test case, one in 2D for input files where NOLIFA = 0, and another one in 3D.

Jason G. Fleming, December 2005